FootRevive™ · Model CHZL-C84GY-C06C · Independent Lab Testing

Every claim, verified by an independent laboratory.

FootRevive was tested by accredited third-party laboratories for photobiological safety, electromagnetic compliance, LED wavelength accuracy, and restricted hazardous substances.

EN 62471 · Exempt Group FCC Part 15 Subpart B · Conform CE EMC · Conform RoHS · Conform Wavelengths Measured · 660 + 850nm

EN 62471:2008 — Photobiological Safety of Lamps and Lamp Systems

Photobiological Safety

Tests whether a light source poses a hazard to skin or eyes across five categories: actinic UV, near-UV, retinal blue-light, retinal thermal, and infrared radiation. The LED emitters used in FootRevive were classified in the Exempt Group — the safest classification the standard allows. The lab’s summary: the radiation from the LED does not exceed the values given in EN 62471:2008.

Classification

EXEMPT

Report No.

EED31R812475

Laboratory

Centre Testing International Group Co., Ltd

Tested

July 29, 2025

Issued

August 8, 2025

Scope

SMD LED emitters · Exempt Group criteria all passed

FCC Part 15 Subpart B — Supplier’s Declaration of Conformity

FCC Compliance

Confirms the device does not emit harmful radio frequency interference, the requirement for any electronic device sold in the United States. The declaration covers model CHZL-C84GY-C06C and is backed by testing at an independent laboratory.

Result

Conform

Declaration No.

LH-240910023667

Laboratory

Shenzhen LH Testing Technology Co., Ltd

Date

September 11, 2024

Standard

FCC Part 15 Subpart B

EN IEC 55014-1:2021 · EN IEC 55014-2:2021 · EN IEC 61000-3-2:2019+A1:2021 · EN 61000-3-3:2013+A2:2021

CE Electromagnetic Compatibility

Tests both electromagnetic emissions and immunity against the four EMC standards that apply to household and similar appliances. Required for EU market compliance under directive 2014/30/EU.

Result

Conform

Certificate No.

2024SZ0506624

Test Report No.

YCT2024SZ0506624E

Date

May 23, 2024

Directive

EU 2014/30/EU

IEC 62321-3-1 · 62321-4 · 62321-5 · 62321-6 · 62321-7-1 · 62321-7-2 · 62321-8

RoHS Compliance

Tests for restricted hazardous substances using ICP-OES, UV-VIS and GC-MS methods: lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and phthalates. All must fall below legal thresholds to pass.

Result

Conform

Reference No.

2024SZ0506625

Test Report No.

YCT2024SZ0506625R

Date

May 23, 2024

Directive

EU 2015/863 amending Annex II to 2011/65/EU


Measured: 656.6nm and 849.8nm.

We specify two wavelengths, 660nm red and 850nm near-infrared. Both were independently measured on an EVERFINE spectroradiometer — every number below is a reading off the instrument, not a manufacturer estimate.

656.6 nm

Red Light · 660nm Nominal

Measured peak wavelength of 656.6nm with a dominant wavelength of 640.1nm and 99.7% colour purity. Spectral output is 99.4% red.

Peak wavelength656.6 nm
Half-width17.8 nm
Radiant flux13.56 mW
Drive current20.01 mA
✓
Verified — EVERFINE Spectral Analysis

849.8 nm

Near-Infrared · 850nm Nominal

Measured peak wavelength of 849.8nm. Near-infrared light in this range penetrates deeper into tissue than visible red light.

Peak wavelength849.8 nm
Half-width27.3 nm
Radiant flux10.17 mW
Drive current20.01 mA
✓
Verified — EVERFINE Spectral Analysis

What “Exempt” means for photobiological safety.

EN 62471 sorts light sources into four groups by hazard potential. Exempt is the safest level — the source poses no photobiological hazard under any of the five tested categories. The LEDs in FootRevive passed every Exempt Group criterion.

Lowest Risk

Exempt Group

No photobiological hazard of any kind.

FootRevive™ LEDs

Risk Group 1

Low Risk

No hazard under normal behavioral limits.

Risk Group 2

Moderate Risk

Hazardous with prolonged direct staring.

Risk Group 3

High Risk

Hazardous even with brief exposure.

About the Testing Laboratories

FootRevive’s certifications come from separate independent laboratories, each testing a different discipline. Nothing on this page was self-certified by the factory.

Centre Testing International Group Co., Ltd

Photobiological Safety · EN 62471

Hongwei Industrial Park, Zone 70, Bao’an District, Shenzhen, Guangdong, China
Report EED31R812475 · Samples received July 21, 2025 · Tested July 29, 2025 · Issued August 8, 2025
Measured at 24.2°C using a photobiological safety performance test system.

Shenzhen LH Testing Technology Co., Ltd

Radio Frequency Emissions · FCC Part 15 Subpart B

106 and 107, Building B15, Yintian Industrial Zone, Yantian Community, Xixiang Street, Bao’an District, Shenzhen
Test report LH-240910023667 · Declaration dated September 11, 2024

EVERFINE Spectral Analysis

LED Wavelength Verification

Measured on LED300 + HAAS2000 spectroradiometer · June 1, 2026
Ambient conditions 25.3°C, 65.0% relative humidity

Device Certified

FootRevive™
Model CHZL-C84GY-C06C

CE & RoHS Certificates

2024SZ0506624 (EMC)
2024SZ0506625 (RoHS)
Issued May 23, 2024

Standards Applied

EN 62471:2008 · FCC Part 15B
EN IEC 55014-1/-2 · EN IEC 61000-3-2/-3-3
IEC 62321 series