FootRevive™ · Model CHZL-C84GY-C06C · Independent Lab Testing
FootRevive was tested by accredited third-party laboratories for photobiological safety, electromagnetic compliance, LED wavelength accuracy, and restricted hazardous substances.
Certification Reports
EN 62471:2008 — Photobiological Safety of Lamps and Lamp Systems
Photobiological Safety
Tests whether a light source poses a hazard to skin or eyes across five categories: actinic UV, near-UV, retinal blue-light, retinal thermal, and infrared radiation. The LED emitters used in FootRevive were classified in the Exempt Group — the safest classification the standard allows. The lab’s summary: the radiation from the LED does not exceed the values given in EN 62471:2008.
Classification
EXEMPT
FCC Part 15 Subpart B — Supplier’s Declaration of Conformity
FCC Compliance
Confirms the device does not emit harmful radio frequency interference, the requirement for any electronic device sold in the United States. The declaration covers model CHZL-C84GY-C06C and is backed by testing at an independent laboratory.
Result
Conform
EN IEC 55014-1:2021 · EN IEC 55014-2:2021 · EN IEC 61000-3-2:2019+A1:2021 · EN 61000-3-3:2013+A2:2021
CE Electromagnetic Compatibility
Tests both electromagnetic emissions and immunity against the four EMC standards that apply to household and similar appliances. Required for EU market compliance under directive 2014/30/EU.
Result
Conform
IEC 62321-3-1 · 62321-4 · 62321-5 · 62321-6 · 62321-7-1 · 62321-7-2 · 62321-8
RoHS Compliance
Tests for restricted hazardous substances using ICP-OES, UV-VIS and GC-MS methods: lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and phthalates. All must fall below legal thresholds to pass.
Result
Conform
Wavelength Verification
We specify two wavelengths, 660nm red and 850nm near-infrared. Both were independently measured on an EVERFINE spectroradiometer — every number below is a reading off the instrument, not a manufacturer estimate.
656.6 nm
Red Light · 660nm Nominal
Measured peak wavelength of 656.6nm with a dominant wavelength of 640.1nm and 99.7% colour purity. Spectral output is 99.4% red.
849.8 nm
Near-Infrared · 850nm Nominal
Measured peak wavelength of 849.8nm. Near-infrared light in this range penetrates deeper into tissue than visible red light.
EN 62471 sorts light sources into four groups by hazard potential. Exempt is the safest level — the source poses no photobiological hazard under any of the five tested categories. The LEDs in FootRevive passed every Exempt Group criterion.
Lowest Risk
Exempt Group
No photobiological hazard of any kind.
FootRevive™ LEDsRisk Group 1
Low Risk
No hazard under normal behavioral limits.
Risk Group 2
Moderate Risk
Hazardous with prolonged direct staring.
Risk Group 3
High Risk
Hazardous even with brief exposure.
FootRevive’s certifications come from separate independent laboratories, each testing a different discipline. Nothing on this page was self-certified by the factory.
Centre Testing International Group Co., Ltd
Photobiological Safety · EN 62471
Hongwei Industrial Park, Zone 70, Bao’an District, Shenzhen, Guangdong, China
Report EED31R812475 · Samples received July 21, 2025 · Tested July 29, 2025 · Issued August 8, 2025
Measured at 24.2°C using a photobiological safety performance test system.
Shenzhen LH Testing Technology Co., Ltd
Radio Frequency Emissions · FCC Part 15 Subpart B
106 and 107, Building B15, Yintian Industrial Zone, Yantian Community, Xixiang Street, Bao’an District, Shenzhen
Test report LH-240910023667 · Declaration dated September 11, 2024
EVERFINE Spectral Analysis
LED Wavelength Verification
Measured on LED300 + HAAS2000 spectroradiometer · June 1, 2026
Ambient conditions 25.3°C, 65.0% relative humidity
Device Certified
FootRevive™
Model CHZL-C84GY-C06C
CE & RoHS Certificates
2024SZ0506624 (EMC)
2024SZ0506625 (RoHS)
Issued May 23, 2024
Standards Applied
EN 62471:2008 · FCC Part 15B
EN IEC 55014-1/-2 · EN IEC 61000-3-2/-3-3
IEC 62321 series